The PowerCURE™ is running and heating, but the display shows no current or power

Possible cause:

There might be a loose connection!

 

Check the connection of the plug J1 on the main board (see picture).

Check the voltage on this plug while running:

white -> black = 0.5 – 1.0 VDC

green – > black = 15 VDC

brown -> black = -15 VDC

 

If you don’t have 0.5-1.0V, please check the wiring of this cable, which goes to a small board inside the of the PM HF.

NOTE:
Check this plug only when the unit is switched off and discharged!