The stripes are crashing into the magnetic conveyor on the 2nd table.

Check function of the reed sensors B256, B257, B258 and B259.

You can find them on the cylinders of the magnetic conveyor (Y125) and transport roll (Y124). Manually activate the two cylinders on the valve block and adjust the reed sensors if necessary.

Refer also to the pneumatic diagram here.