Problem:
The sheet is lifted by the front sucker bar but then dropped instead of being pushed into table 1. After 3 times slitter stop and error message “SEPARATION: Double sheet counter limit” appears.
Possible Causes & Resolutions:
- Check on the HMI whether the correct sheet thickness values has been set.
- Check whether the sheets are sticking to each other or not. If they do, separate the top ones physically from each other and try again to destack them.
- Check the position / correct function of all separation air nozzles left and right: The top sheets should be visually separated.
- Check the position / correct function of all separation magnets left and right: The top sheets should be visually separated.
- If available switch on the separating air between downstacker and 1. table as well, and reset their height if necessary.
- Check the physical setting height of the double sheet sensor: If the sensor is set too high, he will not be in contact with the sheet, resulting in incorrect measurements.
- Check the cable between double sheet sensor and control. There may be a cable break which influences the measurement result. Replace the cable if needed.