HMI “Communication disturbed”
Problem:
HMI communication error (see picture)
Not able to run the welder
Possible Causes & Resolution:
Turn the machine off and back on and see if the error message comes up again.
Check for the LED “on” at the PLC.
The machine isn’t showing any reaction (for example wire manual)
Please check the MPI-bus connection between the touch panel and the PLC.
Also check if all the PLC modules are properly mounted to the c-rail.
The machine was switched off for a longer period.
The PLC has an internal battery. To be sure that it can be sufficient charged, leave the machine power on for >24 hours.
Change the battery of the Pacemaker, see FAQ
PM send error / PM receive error or welding parameter don’t match after starting the machine
.
Operating panel / touchscreen does not work properly, when I touch it with my finger/s
Possible cause:
Between touchscreen and frame there might be dirt or the airgap is too small.
Touchpanel defect.
Scale of the touchscreen surface is not correct.
Contact Can Man use
E-ticket
.
All Can Man content is now also available on the Soudronic Group website.
Where do you want to continue your journey?
stay on the Can Man website
explore the NEW WEBSITE
All Can Man content is now also available on the Soudronic Group website.
Where do you want to continue your journey?
stay on the Can Man website
explore the NEW WEBSITE