Problem:

Some Beckhoff i/o terminals are not active and status LEDs are off, control does not respond to commands.

Possible Causes & Resolutions:

  • The 24Vdc supply of the EK1100 coupler or the EL9410 intermediate supply terminal is missing or the voltage is too low > Check all connections, measure voltage, check fuses.
  • Bad contact between the terminals > Switch off the main power and remove the terminals. Clean the contact between the terminals.
  • Defective EL9410 intermediate supply terminal > Exchange terminal.
  • Defective EK1100 coupler > Exchange coupler.

 

 

 

Problem:

After main switch off and on again, HMI piece counter values and settings are lost or old recipes are loaded.

Possible Causes & Resolutions:

  • IPC has not shut down correctly.Check the IPC after you switched off the main switch: Normally it will continue to run for at least 30 seconds to shut down correctly. If LED’s of IPC goes off within a few second, the battery of the UPS – unit is dead and needs to be replaced.

 

Please follow the below instructions carefully:

  1. Cooling unit for cold water (for both welding rollers):
  • The cooling emulsion must be changed yearly, but more preferably every 6 months. Follow the X7 manual if you have to change the emulsion !
  • The filter cartridge of 50 µm needs to be replaced monthly ! Follow the X7 manual if you have to the filter cartridge !
  • Check the level of the cooling emulsion on the internal tank. If you have to refill the tank, follow the X7 manual to get the correct mixing ratio for the emulsion, and fill the tank. Note: If the water level is too low, the chiller should show an error message, and the X7 should stop and show an error on the iPad !

 

  1. Cooling water / emulsion distribution station on X7:
  • Run some (5 to 10) can bodies and control the water pressure on the manometer: 5.0 bar is the min. required water pressure !
  • Run some (5 to 10) can bodies and control the water flow on the flowmeter S26 (2. From right side): 5.0 liter per minute is the min. water flow.
  • Note: The water pressure switch S120 is set to > 4.0 bar. If there is the error message “Error S120” on the iPad , first check the water pressure on the manometer, and if it’s below 4.0 bar check the cooling unit again !

 

  1. Weld roll ø 42 / 49 / 54 / 62 / 90 mm and lower weld arm:
  • It’s possible that the cooling circuit from waterflow meter S26 to lower weld roll, and back to the outlet on the water distribution, is blocked:

Take off the lower weld roll, unplug the grey water tube ø 10 mm labeled with “àWR” directly at the flow switch S26, and blow into the tube with air pressure. Check the out-going air-pressure at the free hole in the lower weld arm (supply for lower weld roll). If the circuit is free, you feel an equal air pressure (like on the output of the air gun) on your finger tip. If you recently took off the lower weld arm, there might be a problem with one or both o-ring seals between arm and upper bus bar:

 

Please check them if needed !

  • Now unplug the grey tube ø 10 labeled with “WR à” on the water distribution and blow into the tube with air pressure. Check the out-going air-pressure at the free hole in the lower weld arm (exit of lower weld roll). If the circuit is free, you feel an equal air pressure on your finger tip
  • If you re-install the lower weld roll again, make sure that the arrow “running / turning direction” is showing into the right direction.

Before re-connecting both grey tubes ø 10 mm, blow into one tube again by air-pressure, and feel the equal air-pressure on the other tube by your finger tip. If it’s ok, correctly connect both tubes again.

 

  1. Copper wire / copper wire profiling unit:
  • Measure the copper wire profile after the profiling unit on various positions (within around 300 mm). Check the correct width in the X7 manual. The tolerance must be within 0.03 mm !
  • Please check if the wire guiding wheel in front of the lower weld roll is broken. If it’s broken, replace it by a new one. Make sure you choose the correct size 1.90 or 2.30 mm !
  • Please check if the copper wire tension is correct. Set the correct tension according X7 manual !

 

  1. Welding parameters:
  • Please check the weld pressure. Set the correct welding pressure according X7 manual. The range should be between 40 and 50 daN.
  • Please check the welding frequency. Set the correct value according the recommendation in the iPad !
  • Please check the welding overlap. The welded overlap should be nosepiece overlap + 0.1 mm !
  • Check if the IR-Sensor graph of the Qualimaker 2™ on the iPad are within the correct range and straight, which means that the crown and exit conveyor settings are correct:

  1. Other possible errors:
  • If the copper wire gets burned, check if the upper and lower weld roll are touching each other without a blank between. Press the button on the main-aluminium plate to close the welding roller and test it.

Possible cause:

Download PDF here

German instruction: page 52 – 55

English instruction:  page 110 – 113

French instruction:  page 172 – 175

Important requirements:

  1. t2 must be always higher than t1 (t2 > t1).
  2. t2 and t1 must be set lower than 1 cycle time of the machine. For example, if the machine is running with 300 cans/min the cycle time is 200ms. Therefore, t2 and t1 must be set lower than 200ms.
  3. To do an overlap check set  “overlap check” to “ON”. The reduced current will be set automatically to 0A. In the same window you have an additional value. If you set this for example to 10ms you have more unwelded area at the beginning and end of can.NOTE: If you use “overlap check” function is not necessary to switch “Ired” to “ON”.


Possible problems, if the overlap function does not work!

  • If you can’t see the value t2 and t1, maybe the pacemaker is running with “Old” mode and not with “CMX” mode. Change in the setup “CT” from “Old” to “CMX”.
  • No input signal on input 4 (terminal 7 and 8 on pacemaker board). If machine is running, LED behind input 4 (clamp 7 and 8) must flashing. This is the cycle signal to start the timer t2 and t1 for the overlap check.

How is the distance between the clutchring and the switch?
Trigger the clutch by hand and check if the red LED light comes on.

 

This is the LED, which should light up.

 

Try if you can hold the polygon shaft by hand tightly and trigger the clutch and therefore an immediate machine stop.

 

If you need to alter the torque of the clutch, do the following:

 

Loose both black screws of the guiding channel.

 

Pull the channel to the back of the machine.

 

Now you can see the clutch.

 

The basic setting should be 70 NM – see the red mark.

 

Loose the countersunk screw and take the screw out.

 

Turn the clutch clockwise with a special tool or a drift punch and a plastic hammer.

 

You can reduce or increase the torque by steps off 5 Nm, in order to fit the countersunk screw in.
(Picture shows a reduction to 50 Nm)

 

Now push back the channel back into the machine and tighten the black screws.

For further information find the Mayr clutch manual here:

Mayr EAS 450

Mayr Smartic 0-481-325

Please check following points on your CM16 welder:

  • Adjust the tooling with the mandrel. All precalibration rollers have to touch the mandrel slightly.
  • The center of the calibrating crown (diabolo roller) has to be between 1.0 to 2.0mm behind the center of the lower welding roller! Please measure carefully.
  • Check the angularity of all 3 axes of the main calibrating tool plate.
  • Check the height of the front carbide Z-bar (nose- / headpiece). If it is too deep, then it could cause a different overlap.
  • Check the cutting tolerances of the tin plates according our specifications on our webpage.
  • Adjust the welding pressure on the precise air regulator to 2.8 – 3.0 bar.
  • Check the wire gap within 5 – 10 canbodies: The tolerance should not be higher then 1mm.
  • Control the tin layer on the upper and lower copper wire, it has to be in the center.
  • Rollforming has to be parallel, and the blank edges has to be around 5mm overbended.
  • Check the overtravel according the rule on the carriage.
  • Check whether the idler wheel in front of the lower welding roll is in correct position, or whether the circlip is missing (X-plane only)!

Operating Manual CM16 Maintenance Book

Click here

Report all steps, new or different settings, and old and new production parameters (can size, cpm, weld speed, weld current, weld frequency, current wave-form and transformer step) for an easier overview and follow-up ! (www.canman.ch /Open new ticket and add your document)

Note on which tin-plate parameters (thickness, hardness, tin coating inside / outside, rolling direction, BA or CA, supplier, printed or not) such faults occur, and on which tin-plates not !

Basic parameters & settings to be checked first

  1. Tin-plates must be cutted within the allowed tolerances:
    • Measure the tin-plates and report if out of tolerance!
    • Follow sheet „blank-cutting tolerances“! (www.canman.ch/SUPPORT/Canmaking/002)
    • Are all tin-plate parameter clear and noted: Thickness, hardness, tin coating in- and outside, rolling direction, BA or CA, supplier, printed or not
  2. Can-bodies must be correctly rollformed:
    • Not conical and best roundness must be reached!
    • Overlap of both tin-plates edges:
      • ø 52 ~ 5 mm
      • ø 99 ~ 15 mm
      • ø 153 ~ 30 mm
      • ø 284 ~ 60 mm
  3. The copper wire must be correctly profiled and the surface not damaged:
    • The width of the profiled copper wire shall always be 0.05 mm smaller than the profile-groove in the weld rollers!
    • Measure the width of the profiled copper wire within around half a meter on several position, and note the variations. Maximum difference of 0.05 mm is allowed. If you measure more, check the concentricity of the profiling rings.
    • Change the copper wire profiling rings or idler/guide wheels if the surface of the copper wire shows a damage.
  4. Both weld rolls must be regrooved after its regular groove life-span:
    • To avoid unexpected heavy weld faults, it is recommended to implement the total piece-counter and the regrooving interval into the production order!
    • As an example:
      • Upper weld disc ø 90 mm to be regrooved after 3 mio cans (interval depends on, type of welder, type of weld roll and welding speed).
      • Lower weld roll ø 62 mm to be regrooved after 2 mio cans.
      • Example: Total piece counter at production start at 28 mio welded can bodies, upper weld disc has been regrooved at 25 mio, therefore to be regrooved now! Lower weld roll regrooved at 27.5 mio, therefore to be regrooved at 29.5 mio.
    • After every regrooving, weld roll and / or z-bar must be repositioned: Use the correct tools to reset the lower weld roll and/or nose-piece, and the upper welding roller!
  5. The z-bar must be clean in and outside – and not worn -, calibration crown must be clean, and all pre-calibration rollers shall turn easily:
    • A dirty z-bar may not be well insulated, therefore the risk of wear is higher and the weld current is flowing over z-bar and tin-plate to the weld center!
    • Note: The insulation of the secondary circuit should be controlled yearly!
    • Non-turning pre-calibration rollers can create body-offset and inconstant can gap!
  6. The calibration crown center must be correctly positioned to the weld center:
    • The center of the crown must stay between 3 – 0.5 mm before the center of the lower weld roll (in weld direction seen).
  7. The position and speed of the exit conveyor (all conveyors which transport the can body out of the weld center) must be aligned perfectly.
    • Both belts of any V-Shape conveyor need to have a gap of 0.3 – 0.5 mm to the can body. If available use a setting mandrel instead of a can body. The alignment of the conveyor must be absolutely parallel to the weld direction!
    • The gap between two can bodies on the exit conveyor should not be higher than10 – 20 mm! (if can gap is 1.0 – 3.0; see „can gap“ in point 12.)
    • A driven diabolo roller / bottom conveyor after the diabolo rollers must run the same speed like the copper wire!
  8. Both tin-layers must be centered and parallel to the copper wire:
    • That means that all mechanical settings are correct!
  9. The copper wire tension and elongation must be correct:
    • Make sure that the air-pressures for the pneumatical cylinders are set correctly, or the copper wire is in the right groove of the wire drive disc (Soudronic m/c’s only).
    • Measure the copper wire elongation after the lower weld roll, or after the weld roll before the wire chopper: Elongation varies under normal conditions between 0 – 4 % of the can body height.
    • A sufficient copper wire tension is important to avoid a slipping copper wire on the weld rolls!
  10. The can body overtravel must fit:
    • Set the overtravel according manual / scale on the transport carriage!
    • Measure how many mm the can body will be pushed over the center of the weld rolls.
  11. The welding pressure must be set correctly:
    • Welding pressure for Wima welders vary between 35 and 50 kg / daN. Start with ~ 45 kg / daN (if needed check the manual to convert in bar).
    • 50 Hz Wima welders using welding pressure between 35 – 50 kg/daN as well.
  12. The welded overlap must be correct, and on beginning and end within allowed tolerances:
    • Correct welded overlap depending on z-bar:
      • Z-bar of 0.3 mm results in a welded overlap of 0.4 – 0.5 mm
      • Z-bar of 0.4 mm results in a welded overlap of 0.5 – 0.6 mm
      • Z-bar of 0.6 mm results in a welded overlap of 0.6 – 0.7 mm
      • Z-bar of 0.8 mm results in a welded overlap of 0.8 – 0.9 mm
    • If the overlap is not correct, adjust until overlap is correct:
      • Reset the calibration crown if needed with the mandrel. The diabolo-rollers should not have any radial-play!
      • Adjust the overlap according manual.
    • Once the overlap has been set, double check and set the can gap. Increasing the overlap will reduce the can gap, decreasing the overlap will increase the can gap.
    • Weld around 5 cans and measure the gap between the tin-layers. A good can gap measures between 1.0 – 3.0 mm (depending on the can body format). Any variation should be within 0 – 1.0 mm.
  13. The weld current frequency must fit:
    • Welders with a static frequency inverter should have a welding spot length between 0.6 – 1.2 mm.
    • A welder without static frequency inverter should be operated between 8 – 12 m/min. Reducing the welding speed does decrease the welding spot length.
    • The welding spot length should always be as long as possible (by reducing the frequency) to reduce energy and heat in the welding seam and in the welder to a minimum.
    • Main target must be a flexible and smooth welding seam!
  14. The main weld current must be set correctly!
    • How to do:
      • Reduce weld current until cold weld zones appear. Tear-off test must be done at an angle of 30 – 45°, means try to pull-off the top tin plate edge. To be done from each side. Note the weld current value!
      • Increase weld current until hot weld appears. Tear-off test must be done at an angle of 0°, means pull-off the seam only and find out when the seam starts to become fragile. Note the weld current value!
      • Add 2/3 of the weld current difference between cold and hot weld seam to the cold weld seam value, and start the production!
    • Set beginning and end time and beginning and end current!
    • Note: If the welder is running with triangle wave-form, make sure the duty-cycle is between 80 – 90 %. If the welder is running with sine wave-form, make sure the right transformer step has been choosen! Contact us if you are not sure.
  15. The seam-extrusion inside and outside must be equal!
    • If the seam extrusion is bigger inside, reduce the height of the calibration crown. If the seam extrusion is bigger outside, increase the height of the calibration crown.

 

Checklist to Avoid Micro Leaks

Micro leaks can occur within the seam and beside the seam – especially on cold-formed areas like necking, beading, flanging or seaming -, even if all above mentioned basic parameters & settings seems to be correct.

Micro leaks can have various sources: Wrong settings on the welder, tin-plate parameters which support such faults, worn or wrong machineries in the downline, or tin-plate parameters which do not fit to beader, necker, flanger and seamer.

For a better visual understanding put the faulty-can bodies in a water bath, and inspect the leaking area by a microscope. Store the pictures if possible!

  1. Make sure that necker, flanger, beader and seamer are in good condition, and do not stress the weld seam more than needed.
    • For further information check the manuals (check the tin-plate specifications range) or contact the supplier!
  2. Try to weld different tin-plates to understand which tin-plate parameter can be produced without such faults.
    • Rolling-direction parallel to weld seam can increase the occurrence of micro-leaks!
  3. Micro-leaks in and near the seam can be reduced by changing the energy in each welding spot:
    • Reduce the welding frequency within the possible range (see point 13. in above checklist), and set the main weld current again (see point 14. in above checklist). The production cycle (cpm) must probably be reduced to reach a good weld seam. Produce a certain number of cans and test them.
    • Increase the welding frequency within the possible range, and set the current again. Produce a certain number of cans and test them.
    • Reduce the welding pressure to max 45 kg / daN, and set the main weld current again (see point 14. in above checklist). Produce a certain number of cans and test them.
    • Reduce the welded overlap by around 0.10 mm, and set the main weld current (see point 14. in above checklist). Produce a certain number of cans and test them.

 

Checklist to Avoid Flange-Cracks

Flange cracks can occur at the beginning and the end of the seam, even if all above mentioned basic parameters & settings seems to be correct.

Flange cracks can have various sources: Wrong settings on the welder, tin-plate parameters – for instant parallel rolling direction – which support such faults, worn or wrong flanger in the downline, or tin-plate parameters which do not fit to the flanger and or seamer.

For a better visual understanding put the faulty-can bodies in a water bath, and inspect the leaking area by a microscope. Store the pictures if possible!

  1. Make sure that flanger and seamer are in good condition, and do not stress the weld seam more than needed:
    • For further information check the manuals (check the tin-plate specifications range) or contact the supplier!
  2. Try to weld different tin-plates to understand which tin-plate parameter can be produced without such faults:
    • Rolling-direction parallel to weld seam will increase flange cracks, because the seam cracks in line with the rolling direction!
    • Weld tin-plates with cross rolling direction and test them.
  3. Flange cracks can be reduced by changing the energy in each welding spot:
    • Reduce the welding frequency within the possible range (see point 13. in above checklist), and set the main weld current again (see point 14. in above checklist). The production cycle (cpm) must probably be reduced to reach a good weld seam. Produce a certain number of cans and test them.
    • Increase the welding frequency within the possible range, and set the current again. Produce a certain number of cans and test them.
    • Reduce the welding pressure to max 45 kg / daN, and set the main weld current again (see point 14. in above checklist). Produce a certain number of cans and test them.
    • Reduce the welded overlap by around 0.10 mm, and set the main weld current (see point 14. in above checklist). Produce a certain number of cans and test them.
    • Activate the current reduction on the begin and end to reduce the heat in the first few welding spots.
  4. If above listed does not help, some theoretically wrong settings could help:
    • Increase the can gap to have completely different welded begin and end. Produce a certain number of cans and test them, and set back if it didn’t help!
    • Set a slight can-body offset, to bring the current different into the tin-plate. Produce a certain number of cans and test them, and set back if it didn’t help!
All Can Man content is now also available on the Soudronic Group website.
Where do you want to continue your journey?
All Can Man content is now also available on the Soudronic Group website.
Where do you want to continue your journey?