Support

4 Support Entries

How to bypass / remove a generator in case of failure on the PowerCURE V2 please check link below:

CM26 bypass generator in case of failure

How To:

  1. Switch off cooling unit.
  2. Switch off main power. Wait 10 min until the capacitors inside PM HF are discharged before removing cover.
  3. Before you remove any cable, take some picture and note how they are connected.
  4. Disconnect the cables and water tubes on the c-bank.
  5. Disconnect the Powercable and the water tubes on PM HF unit.
  6. Disconnect the signal cable (Plug Sub D 25 Pin) and the panel cable (Plug Sub D 9 Pin).
  7. Disconnect the two valve cables inside PM HF.
  8. Remove the PM HF and replace with new or spare unit.
  9. Reconnect all cables.
  10. ATTENTION: Check the coil before connecting it!
  11. Double check all connection before switching on the main power.
  12. Compare the settings/parameter and change it if necessary. For instructions which parameters has to set and how to do please contact Can Man
  13. Re-start the PowerCURE™

Reason for error message:

  • The Pacemaker™ HF has detected a missing phase.

 

Possible causes:

  • Supply voltage mains (all three phases) 400V
  • Check the small fuses on the bottom of Pacemaker HF
  • Check complete wiring, Are all clamps tightened?
  • Measuring voltage at the input terminals on the main board (see attached picture)
  • IC “OC14” or phase measurement is defective. Replace the IC, Type HCPL3700

Possible cause:

  • Check if the wire speed is stable and not too slow? Sometimes two cans might be welded together (no gap)!
  • Check if the speed of the exit conveyor is fast enough? The gap between the cans must be minimum of 10mm.
  • Clean the first light barrier and the reflector and check the adjustment!
All Can Man content is now also available on the Soudronic Group website.
Where do you want to continue your journey?
All Can Man content is now also available on the Soudronic Group website.
Where do you want to continue your journey?