The Pacemaker™ static welding inverter has a RAM battery for data retention and clock-buffering at power interruption/disconnection. The battery has a limited life span (about 5 years) that decreases especially without power supply (controller off). To prevent loss of data, the battery must be replaced early enough > ONLY BY AUTHORIZED AND SKILLED PERSONNEL!

To order a new battery please contact spares.canman@soudronic.com.

For instructions on how to replace the battery use the download link below. You will also find the correct order number there.

Download instruction

 

How to change the battery on a Pacemaker™ with integrated Qualimaker V1 electronic board:

  1. Turn off the main switch of the welder.
  2. Wait at least 5min to discharge the capacitors.
  3. Remove all 4 nuts which are fixing the Qualimaker V1 electronic board on top of the Pacemaker™.
  4. Disconnect plug 1 acc. attached picture.
  5. Mark both wires 2 acc. attached picture and make a picture how they are connected.
  6. Disconnect both wires 2 and insulate their ends.
  7. Now the electronic board can be lifted to have access to the battery.
  8. Press the emergency stop button and turn on the main switch to power the Pacemaker™: This way the settings will not be lost when changing the battery !
  9. Follow the instructions for replacing the battery => Download instruction
  10. After the battery has been replaced, turn off the main switch and reconnect everything.
  11. Before switching on the main switch, check all connections again to make sure they are correct and tight.

 