Support

1 Support Entries

Requirement:

  • The cooling energy should be 3 kW or more.
  • Cooling water temperature not below 20°C, due to the condensation at the coil.
  • The water pump should be able to generate a min. of 4 bar pressure at the inlet of the PowerCURE™ with a pump capacity of min. 10l/min.

Customer options:

  1. You buy your cooling system – you are responsible for the required technical data.
  2. You’re planning to buy a larger cooling unit for the PowerCURE™ and the welder, you must add the data of both systems requirement together. Ask the original welder manufacturer for the cooling data and remember; if the cooling water for the welder is required to be below 20° C, you must split the system in two circuits with independently adjustable temperatures.
  3. You order the cooling unit at CanMan.
  4. You buy a CanMan welding machine with seam protection and a PowerCURE™. In this case we will deliver a combined cooling unit, which cools the welding and the PowerCURE™ unit.
All Can Man content is now also available on the Soudronic Group website.
Where do you want to continue your journey?
All Can Man content is now also available on the Soudronic Group website.
Where do you want to continue your journey?