Please follow the below instructions carefully:

  1. Cooling unit for cold water (for both welding rollers):
  • The cooling emulsion must be changed yearly, but more preferably every 6 months. Follow the X7 manual if you have to change the emulsion !
  • The filter cartridge of 50 µm needs to be replaced monthly ! Follow the X7 manual if you have to the filter cartridge !
  • Check the level of the cooling emulsion on the internal tank. If you have to refill the tank, follow the X7 manual to get the correct mixing ratio for the emulsion, and fill the tank. Note: If the water level is too low, the chiller should show an error message, and the X7 should stop and show an error on the iPad !

 

  1. Cooling water / emulsion distribution station on X7:
  • Run some (5 to 10) can bodies and control the water pressure on the manometer: 5.0 bar is the min. required water pressure !
  • Run some (5 to 10) can bodies and control the water flow on the flowmeter S26 (2. From right side): 5.0 liter per minute is the min. water flow.
  • Note: The water pressure switch S120 is set to > 4.0 bar. If there is the error message “Error S120” on the iPad , first check the water pressure on the manometer, and if it’s below 4.0 bar check the cooling unit again !

 

  1. Weld roll ø 42 / 49 / 54 / 62 / 90 mm and lower weld arm:
  • It’s possible that the cooling circuit from waterflow meter S26 to lower weld roll, and back to the outlet on the water distribution, is blocked:

Take off the lower weld roll, unplug the grey water tube ø 10 mm labeled with “àWR” directly at the flow switch S26, and blow into the tube with air pressure. Check the out-going air-pressure at the free hole in the lower weld arm (supply for lower weld roll). If the circuit is free, you feel an equal air pressure (like on the output of the air gun) on your finger tip. If you recently took off the lower weld arm, there might be a problem with one or both o-ring seals between arm and upper bus bar:

 

Please check them if needed !

  • Now unplug the grey tube ø 10 labeled with “WR à” on the water distribution and blow into the tube with air pressure. Check the out-going air-pressure at the free hole in the lower weld arm (exit of lower weld roll). If the circuit is free, you feel an equal air pressure on your finger tip
  • If you re-install the lower weld roll again, make sure that the arrow “running / turning direction” is showing into the right direction.

Before re-connecting both grey tubes ø 10 mm, blow into one tube again by air-pressure, and feel the equal air-pressure on the other tube by your finger tip. If it’s ok, correctly connect both tubes again.

 

  1. Copper wire / copper wire profiling unit:
  • Measure the copper wire profile after the profiling unit on various positions (within around 300 mm). Check the correct width in the X7 manual. The tolerance must be within 0.03 mm !
  • Please check if the wire guiding wheel in front of the lower weld roll is broken. If it’s broken, replace it by a new one. Make sure you choose the correct size 1.90 or 2.30 mm !
  • Please check if the copper wire tension is correct. Set the correct tension according X7 manual !

 

  1. Welding parameters:
  • Please check the weld pressure. Set the correct welding pressure according X7 manual. The range should be between 40 and 50 daN.
  • Please check the welding frequency. Set the correct value according the recommendation in the iPad !
  • Please check the welding overlap. The welded overlap should be nosepiece overlap + 0.1 mm !
  • Check if the IR-Sensor graph of the Qualimaker 2™ on the iPad are within the correct range and straight, which means that the crown and exit conveyor settings are correct:

  1. Other possible errors:
  • If the copper wire gets burned, check if the upper and lower weld roll are touching each other without a blank between. Press the button on the main-aluminium plate to close the welding roller and test it.

Download regrooving datasheet

 

Possible causes:

  1. The serial reduce (Powerfoil) is active
  2. Timing from the welding pressure to vacuum “ON” is too short
  3. Wrong setting of t1 & t2
  4. Mechanical setting might need to be adjusted
    (only for unwelded sections at the beginning)

Possible cause:
The upper pendulum roller might be not leveled properly. When regrooving the upper disc for example 0.50 mm in diameter, the height of the pendulum rollerhead must be reduced 0.25 mm. This can be done by the M10 screw on the back side.

See also in the manual X1 how to reset the upper pendulum rollerhead.

NOTE: The description manual is based on a CM X1 welder, but it works very similar for our other welders.

ATTENTION: Do not touch the red marked screws!

Possible causes:

  • Check the blank cutting tolerances and blank squareness.
  • Adjust the rollformer (roller shaft clearance and spring pressure) according to the manual.
  • Control if there is a high difference in the tin plate hardness, by rollforming 10 bodies without welding. Put them on the floor in line and compare the difference in the rollforming overlap.
  • Check if the destacking process is going well. Make sure the tin plate is guided tight, and the separating air is positioned well.
  • Control the timing of the tin plate transport in between two transport fingers.
  • Make sure that the guidance channel is properly adjusted. The intersection to the precalibration of the calibration crown is most important.
  • Check the position of each (inside and outside!) transport finger compared to rollformed canbody.
  • Check the offset of each finger pair itself. Move the canbody slowly forward (X1 and X6 by slow mode function) and observe eventual shaking of the canbody until the welding point.
  • If a third finger exists: The third finger must be 0.5 mm behind the upper main pusher fingers!
  • Reset the calibration crown completely. Make sure that each precalibration roller is turning easily! If needed lubricate their shafts slightly and clean the roller afterwards. Make sure that these rollers are as close as possible to each other!
  • Measure the speed of the flat belt in the calibration crown:
    The speed must be absolutely identical with the copper wire speed!
  • Measure the overtravel: Short can heights shall have 1 mm overtravel.
  • The center of the diabolo roller (equal to the center of calibration crown) shall be 1–2 mm before the welding center.

Use a common Ohmmeter, as you can see on the picture.

 

Measure the resistance between left carbide ring and main aluminum plate.
The measuring result on the Ohmmeter must be endless!

 

Measure the resistance between left carbide ring and main aluminum plate.
The measuring result on the Ohmmeter must be endless!

 

Measure between left and right carbide ring. The result on the Ohmmeter must be endless! This step is to ensure the proper insulation of both rear insulation rings around the taper roller bearings!

 

The picture shows the correct measuring result on the screen of the Ohmmeter for all three test points!

Download PDF here

This is the result of a wrong flexer setting!

Open the rollformer and you undo the screw on the right handside of the “Flexer”.  

Measure with a ruler the actual position of the flexing wedge.

On the other side of the flexer, you can alter the position of flexer with the M8 screw. Choose a lower position for less flexing.

NOTE:
With more flexing the sheet comes out of the flexer station with less prebending.

If you do less flexing, means that the sheet comes out of the flexer station with more prebending.

NOTE:
After adjusting the flexer, you might have to adjust the rounding slighty!
For more information regarding the flexer and rollformer setting check our manual book 2 chapter 5.4.

Possible cause:

  1. Check the water filters:
    When Power ROLL is in use, there is a 50µm filter cartridge in a white body, normally placed on the delivered chiller.
    See also in the manual (chapter 7) how often the filter should be exchanged, and after what time the emulsion has to be exchanged!When mercury rollers are in use, there is a little 250µm filter mounted in the inlet of the water station. Open the filter and blow off the insert til the meshwork is clean.
  2. The water pressure on the water station must show minimum 5.0 bar!
  3. The flow meter of the lower welding roller must show minimum 5.0 l/min!
  4. Take off the water tube in the outlet of that cooling circuit, and measure how many liters emulsion/water is coming out per minute.  Compare that value with the adjusted value on the flow meter. The value of the water flow should be around 1 liter higher than the flow meter, or the flow meter should stay at least at 5 l/min.
  5. If less than 5 liters is coming out, do the following:
    Take off the X-Plane welding roller support completely, and check whether both round connections (center of rotation) between arm and X-Plane are correct positioned! If they are turned, means positioned wrong, they may reduce/close the water circulation between arm and welding roller!Put the X-Plane and welding roller back, and blow out the whole circuit by compressed air.Take off the water tube in the outlet of that cooling circuit, and measure how many liters emulsion/water is coming out per minute. Now the welding arm and roller should remain chilly again.
  6. Adjust now the flow meter to 5.0 l/min and start the production. If everything is correct, the production will not be stopped.
  7. Adjust now the flow meter to the max, means completely to the top, and try to start the production. There should occur an error message on the touch screen, showing that this cooling circuit has not enough water, and production can not being started.

Possible cause:

  • Maintain the calibration crown according to the manual (Book 2; chapter 5.5.4.)
    Important: All precalibration rollers must turn smoothly, not one should be blocked.
  • Reset the calibration crown according Resetting of the tooling
  • Guideline: The higher the production speed, the more difficult to control body offset issues!
  • Tin deposit on z-bar grooves
  • Rollforming not enough

Special settings:

  • The setting of the first, second and probably third spring tensioned rollers before the diabolo roller crown may vary in setting.
  • Basic setting – first, second and – depend on can height – also third rollers should have 0.10 mm movement.
  • If the body offset still remain, start to undo all the nuts of the first pre-calibration rollers by a sixth turn, and so on.
  • Check whether the Z-bar grooves are clean or full of tin/steel pick up:
    • If the grooves are full, clean them by sandpaper 400 or higher. For better cleaning take off the lower welding arm completely. Switch off the chiller before start to dismantle!
    • Check the insulation according manual – How to do an insulation check (yearly task)?
    • Check whether the secondary circuit – lower arm side – is connected to ground by a separate green/yellow cable!

Report all steps, new or different settings, and old and new production parameters (can size, cpm, weld speed, weld current, weld frequency, current wave-form and transformer step) for an easier overview and follow-up ! (www.canman.ch /Open new ticket and add your document)

Note on which tin-plate parameters (thickness, hardness, tin coating inside / outside, rolling direction, BA or CA, supplier, printed or not) such faults occur, and on which tin-plates not !

Basic parameters & settings to be checked first

  1. Tin-plates must be cutted within the allowed tolerances:
    • Measure the tin-plates and report if out of tolerance!
    • Follow sheet „blank-cutting tolerances“! (www.canman.ch/SUPPORT/Canmaking/002)
    • Are all tin-plate parameter clear and noted: Thickness, hardness, tin coating in- and outside, rolling direction, BA or CA, supplier, printed or not
  2. Can-bodies must be correctly rollformed:
    • Not conical and best roundness must be reached!
    • Overlap of both tin-plates edges:
      • ø 52 ~ 5 mm
      • ø 99 ~ 15 mm
      • ø 153 ~ 30 mm
      • ø 284 ~ 60 mm
  3. The copper wire must be correctly profiled and the surface not damaged:
    • The width of the profiled copper wire shall always be 0.05 mm smaller than the profile-groove in the weld rollers!
    • Measure the width of the profiled copper wire within around half a meter on several position, and note the variations. Maximum difference of 0.05 mm is allowed. If you measure more, check the concentricity of the profiling rings.
    • Change the copper wire profiling rings or idler/guide wheels if the surface of the copper wire shows a damage.
  4. Both weld rolls must be regrooved after its regular groove life-span:
    • To avoid unexpected heavy weld faults, it is recommended to implement the total piece-counter and the regrooving interval into the production order!
    • As an example:
      • Upper weld disc ø 90 mm to be regrooved after 3 mio cans (interval depends on, type of welder, type of weld roll and welding speed).
      • Lower weld roll ø 62 mm to be regrooved after 2 mio cans.
      • Example: Total piece counter at production start at 28 mio welded can bodies, upper weld disc has been regrooved at 25 mio, therefore to be regrooved now! Lower weld roll regrooved at 27.5 mio, therefore to be regrooved at 29.5 mio.
    • After every regrooving, weld roll and / or z-bar must be repositioned: Use the correct tools to reset the lower weld roll and/or nose-piece, and the upper welding roller!
  5. The z-bar must be clean in and outside – and not worn -, calibration crown must be clean, and all pre-calibration rollers shall turn easily:
    • A dirty z-bar may not be well insulated, therefore the risk of wear is higher and the weld current is flowing over z-bar and tin-plate to the weld center!
    • Note: The insulation of the secondary circuit should be controlled yearly!
    • Non-turning pre-calibration rollers can create body-offset and inconstant can gap!
  6. The calibration crown center must be correctly positioned to the weld center:
    • The center of the crown must stay between 3 – 0.5 mm before the center of the lower weld roll (in weld direction seen).
  7. The position and speed of the exit conveyor (all conveyors which transport the can body out of the weld center) must be aligned perfectly.
    • Both belts of any V-Shape conveyor need to have a gap of 0.3 – 0.5 mm to the can body. If available use a setting mandrel instead of a can body. The alignment of the conveyor must be absolutely parallel to the weld direction!
    • The gap between two can bodies on the exit conveyor should not be higher than10 – 20 mm! (if can gap is 1.0 – 3.0; see „can gap“ in point 12.)
    • A driven diabolo roller / bottom conveyor after the diabolo rollers must run the same speed like the copper wire!
  8. Both tin-layers must be centered and parallel to the copper wire:
    • That means that all mechanical settings are correct!
  9. The copper wire tension and elongation must be correct:
    • Make sure that the air-pressures for the pneumatical cylinders are set correctly, or the copper wire is in the right groove of the wire drive disc (Soudronic m/c’s only).
    • Measure the copper wire elongation after the lower weld roll, or after the weld roll before the wire chopper: Elongation varies under normal conditions between 0 – 4 % of the can body height.
    • A sufficient copper wire tension is important to avoid a slipping copper wire on the weld rolls!
  10. The can body overtravel must fit:
    • Set the overtravel according manual / scale on the transport carriage!
    • Measure how many mm the can body will be pushed over the center of the weld rolls.
  11. The welding pressure must be set correctly:
    • Welding pressure for Wima welders vary between 35 and 50 kg / daN. Start with ~ 45 kg / daN (if needed check the manual to convert in bar).
    • 50 Hz Wima welders using welding pressure between 35 – 50 kg/daN as well.
  12. The welded overlap must be correct, and on beginning and end within allowed tolerances:
    • Correct welded overlap depending on z-bar:
      • Z-bar of 0.3 mm results in a welded overlap of 0.4 – 0.5 mm
      • Z-bar of 0.4 mm results in a welded overlap of 0.5 – 0.6 mm
      • Z-bar of 0.6 mm results in a welded overlap of 0.6 – 0.7 mm
      • Z-bar of 0.8 mm results in a welded overlap of 0.8 – 0.9 mm
    • If the overlap is not correct, adjust until overlap is correct:
      • Reset the calibration crown if needed with the mandrel. The diabolo-rollers should not have any radial-play!
      • Adjust the overlap according manual.
    • Once the overlap has been set, double check and set the can gap. Increasing the overlap will reduce the can gap, decreasing the overlap will increase the can gap.
    • Weld around 5 cans and measure the gap between the tin-layers. A good can gap measures between 1.0 – 3.0 mm (depending on the can body format). Any variation should be within 0 – 1.0 mm.
  13. The weld current frequency must fit:
    • Welders with a static frequency inverter should have a welding spot length between 0.6 – 1.2 mm.
    • A welder without static frequency inverter should be operated between 8 – 12 m/min. Reducing the welding speed does decrease the welding spot length.
    • The welding spot length should always be as long as possible (by reducing the frequency) to reduce energy and heat in the welding seam and in the welder to a minimum.
    • Main target must be a flexible and smooth welding seam!
  14. The main weld current must be set correctly!
    • How to do:
      • Reduce weld current until cold weld zones appear. Tear-off test must be done at an angle of 30 – 45°, means try to pull-off the top tin plate edge. To be done from each side. Note the weld current value!
      • Increase weld current until hot weld appears. Tear-off test must be done at an angle of 0°, means pull-off the seam only and find out when the seam starts to become fragile. Note the weld current value!
      • Add 2/3 of the weld current difference between cold and hot weld seam to the cold weld seam value, and start the production!
    • Set beginning and end time and beginning and end current!
    • Note: If the welder is running with triangle wave-form, make sure the duty-cycle is between 80 – 90 %. If the welder is running with sine wave-form, make sure the right transformer step has been choosen! Contact us if you are not sure.
  15. The seam-extrusion inside and outside must be equal!
    • If the seam extrusion is bigger inside, reduce the height of the calibration crown. If the seam extrusion is bigger outside, increase the height of the calibration crown.

 

Checklist to Avoid Micro Leaks

Micro leaks can occur within the seam and beside the seam – especially on cold-formed areas like necking, beading, flanging or seaming -, even if all above mentioned basic parameters & settings seems to be correct.

Micro leaks can have various sources: Wrong settings on the welder, tin-plate parameters which support such faults, worn or wrong machineries in the downline, or tin-plate parameters which do not fit to beader, necker, flanger and seamer.

For a better visual understanding put the faulty-can bodies in a water bath, and inspect the leaking area by a microscope. Store the pictures if possible!

  1. Make sure that necker, flanger, beader and seamer are in good condition, and do not stress the weld seam more than needed.
    • For further information check the manuals (check the tin-plate specifications range) or contact the supplier!
  2. Try to weld different tin-plates to understand which tin-plate parameter can be produced without such faults.
    • Rolling-direction parallel to weld seam can increase the occurrence of micro-leaks!
  3. Micro-leaks in and near the seam can be reduced by changing the energy in each welding spot:
    • Reduce the welding frequency within the possible range (see point 13. in above checklist), and set the main weld current again (see point 14. in above checklist). The production cycle (cpm) must probably be reduced to reach a good weld seam. Produce a certain number of cans and test them.
    • Increase the welding frequency within the possible range, and set the current again. Produce a certain number of cans and test them.
    • Reduce the welding pressure to max 45 kg / daN, and set the main weld current again (see point 14. in above checklist). Produce a certain number of cans and test them.
    • Reduce the welded overlap by around 0.10 mm, and set the main weld current (see point 14. in above checklist). Produce a certain number of cans and test them.

 

Checklist to Avoid Flange-Cracks

Flange cracks can occur at the beginning and the end of the seam, even if all above mentioned basic parameters & settings seems to be correct.

Flange cracks can have various sources: Wrong settings on the welder, tin-plate parameters – for instant parallel rolling direction – which support such faults, worn or wrong flanger in the downline, or tin-plate parameters which do not fit to the flanger and or seamer.

For a better visual understanding put the faulty-can bodies in a water bath, and inspect the leaking area by a microscope. Store the pictures if possible!

  1. Make sure that flanger and seamer are in good condition, and do not stress the weld seam more than needed:
    • For further information check the manuals (check the tin-plate specifications range) or contact the supplier!
  2. Try to weld different tin-plates to understand which tin-plate parameter can be produced without such faults:
    • Rolling-direction parallel to weld seam will increase flange cracks, because the seam cracks in line with the rolling direction!
    • Weld tin-plates with cross rolling direction and test them.
  3. Flange cracks can be reduced by changing the energy in each welding spot:
    • Reduce the welding frequency within the possible range (see point 13. in above checklist), and set the main weld current again (see point 14. in above checklist). The production cycle (cpm) must probably be reduced to reach a good weld seam. Produce a certain number of cans and test them.
    • Increase the welding frequency within the possible range, and set the current again. Produce a certain number of cans and test them.
    • Reduce the welding pressure to max 45 kg / daN, and set the main weld current again (see point 14. in above checklist). Produce a certain number of cans and test them.
    • Reduce the welded overlap by around 0.10 mm, and set the main weld current (see point 14. in above checklist). Produce a certain number of cans and test them.
    • Activate the current reduction on the begin and end to reduce the heat in the first few welding spots.
  4. If above listed does not help, some theoretically wrong settings could help:
    • Increase the can gap to have completely different welded begin and end. Produce a certain number of cans and test them, and set back if it didn’t help!
    • Set a slight can-body offset, to bring the current different into the tin-plate. Produce a certain number of cans and test them, and set back if it didn’t help!

Possible cause:

  • Check the wire groove, maybe the profil is not straight anymore (see also if short near the seam).
  • Too much welding current.
  • Too low welding frequency.
  • Check the tension the belt for the profiling unit and pendulum rollerhead.
  • Servo drive transport belt: Check if the whole transport belt  unit is vibrating during positioning. If yes: Change the drive gear on top the servo motor.

Possible cause /checklist:

  • Check all terminals at the Pacemaker board.
    • wait for 5 minutes after switching off the unit).
  • Check the welding pressure: Display > 35 daN!
  • Are the time settings t1 and t2 correct?
  • Is the weld power limiter switched „ON“? Which mode is chosen? Glueing?

Possible causes:

  • The timing of the rounding process is too late.
  • The rolled can body is clamped or caulked in the catch station.
  • One or more transport fingers is / are twisted or lost.
  • The tension of one or both transport finger timing belts is too low.
  • Check the transport finger’s offset.
  • The final pusher fingers of the Synchrostar are taking over the can body from the transport fingers too late.
  • The precalibration is set too tight, or some precalibration rollers are not easily turning anymore.
  • Check if any groove of the z-bar section is worn.

Possible causes/checklist:

  1. Take the wire and switch out of the air supply. Can you smoothly move both cylinders of the wire drive?
  2. Check all rolls of wire drive system. Turn them by hand. All bearings ok?
  3. Check the transport wheel of wire chopper unit, condition and distance (acc. to instruction manual)
  4. Remove the belt of the motor for pendulum roller head and turn them by hand. Is it turning smoothly?
  5. Check the same on profiling and chopper unit.
  6. Now install the belts and tight them correctly.
  7. Put in the wire and adjust the air regulator.
    Cylinder wire profiling unit 1.5 bar and cylinder wire chopper unit 2.0 bar.
  8. Change the selector switch to “wire manual” and run the wire.
  9. Take a look at welding rolls – is wire position correct?
  10. Check profiling of copper wire, correct width and constant?
  11. Weld a can with current and without current. Wire break?
  12. Have you changed the wire? Use the old one to compare.
  13. Check the tin mark on the wire. Ok?
  14. Don’t forget to lubricate the profiling unit and chopper unit.
All Can Man content is now also available on the Soudronic Group website.