Support

3 Support Entries

Use a common Ohmmeter, as you can see on the picture.

 

Measure the resistance between left carbide ring and main aluminum plate.
The measuring result on the Ohmmeter must be endless!

 

Measure the resistance between left carbide ring and main aluminum plate.
The measuring result on the Ohmmeter must be endless!

 

Measure between left and right carbide ring. The result on the Ohmmeter must be endless! This step is to ensure the proper insulation of both rear insulation rings around the taper roller bearings!

 

The picture shows the correct measuring result on the screen of the Ohmmeter for all three test points!

Download PDF here

This might be possible, because the triggering is inverse (this means with a minimal distance to the sensor, it results a max. frequency.

  • Check the distance of the analog sensor (description).
  • If this doesn’t help, place the programming display on the converter U6 and change the parameter C26 from –50% to –55%.